ISO 9626 is a critical international standard that specifies the requirements and test methods for stainless steel tubing used in medical applications, particularly in the manufacture of needles and cannulae. This standard ensures that the tubing meets specific mechanical, dimensional, and material properties essential for safety, reliability, and performance in medical environments.
This guide provides an in-depth analysis of ISO 9626, including its scope, requirements, and practical considerations for manufacturers, quality assurance professionals, and regulatory compliance specialists.
ISO 9626 is typically used in the framework of design verification and validation, which is a topic that we have been discussing extensively, for example dealing with biocompatibility, DHF organization, ISO 14937, GSPR and much more.
Scope of ISO 9626
ISO 9626 applies to stainless steel tubing used in manufacturing hypodermic needles and other medical devices requiring precise mechanical and chemical properties.
The standard defines the required chemical composition of stainless steel, ensuring consistency and quality. It also specifies mechanical properties such as tensile strength, elongation, and hardness, which determine the durability and performance of the tubing.
Dimensional tolerances, including outer and inner diameters as well as wall thickness, are strictly controlled to maintain precision and functionality. Additionally, the standard mandates a smooth surface finish and cleanliness to enhance product reliability and minimize contamination risks.
To ensure long-term durability, ISO 9626 includes corrosion resistance requirements, helping the material withstand sterilization processes and repeated usage.
-
Design Control Package€169,00
Key Requirements of ISO 9626
1. Material Composition
ISO 9626 mandates that stainless steel used for medical tubing must conform to specific chemical compositions. The most commonly used materials are austenitic stainless steel, such as 304 and 316L, known for their excellent corrosion resistance and biocompatibility. Martensitic stainless steel, such as 420, is preferred when higher hardness and strength are required, as in surgical instruments and hypodermic needles.
Manufacturers must conduct chemical analysis to verify material composition and ensure compliance with the standard.
2. Mechanical Properties as per ISO 9626
Mechanical properties are crucial for ensuring the tubing performs reliably in medical applications.
a) Tensile Strength
The tubing must have adequate tensile strength to endure insertion into the body without bending or breaking. The minimum tensile strength is determined based on tube diameter and thickness.
b) Elongation
Elongation measures the ductility of the material and its ability to withstand stretching without breaking. A higher elongation percentage ensures better flexibility, reducing the risk of fractures during use.
c) Hardness
Hardness testing ensures that the tubing is not too brittle, reducing the likelihood of breakage. Common hardness testing methods include Rockwell and Vickers hardness tests.
3. Dimensional Tolerances
Precise dimensional control is essential for compatibility with medical devices. ISO 9626 specifies strict tolerances for outer diameter (OD), wall thickness, and inner diameter (ID). Maintaining these tolerances ensures a proper fit with syringes and other medical components. Manufacturers must use precision measuring tools such as micrometers and calipers to verify dimensional accuracy.
4. Surface Finish and Cleanliness
The standard requires a smooth, defect-free surface to minimize patient discomfort and prevent contamination. Tubing must be free from visible scratches, cracks, and inclusions that could compromise structural integrity. Surface roughness is controlled to optimize fluid flow and reduce resistance during injections. Cleaning procedures must effectively remove residual lubricants and contaminants from the manufacturing process.
5. Corrosion Resistance
ISO 9626 mandates corrosion resistance testing to prevent material degradation during sterilization and prolonged use. Tests include:
- Salt Spray Test (ASTM B117 or equivalent): Evaluates resistance to saline environments.
- Autoclave Resistance Testing: Ensures the tubing withstands repeated steam sterilization cycles.
- Electrochemical Testing: Measures resistance to pitting and crevice corrosion.
Practical Tips for Compliance with ISO 9626
1. Source High-Quality Stainless Steel
Work with reputable suppliers that provide certified medical-grade stainless steel. Always require material certificates verifying compliance with ISO 9626 chemical composition standards.
2. Implement Rigorous Quality Control Measures
Use non-destructive testing (NDT) methods such as eddy current and ultrasonic testing to detect surface and internal defects. Conduct tensile, elongation, and hardness tests on sample batches to confirm mechanical properties.
3. Maintain Tight Dimensional Controls
Utilize precision CNC cutting and grinding machines to achieve required tolerances. Regularly calibrate measurement instruments to maintain accuracy and consistency.
4. Optimize Surface Finishing Techniques
Use electropolishing or passivation to enhance corrosion resistance and surface smoothness. Implement automated cleaning processes to remove contaminants and ensure compliance with cleanliness standards.
5. Conduct Periodic Corrosion Resistance Testing
Simulate real-world sterilization conditions to assess long-term material durability. Store sample materials in saline environments to test stability and performance over time.
6. Maintain Compliance with ISO 9626 Thorough Documentation for Audits
Keep comprehensive records of material certifications, test results, and manufacturing logs. Ensure traceability of each batch to demonstrate compliance during regulatory inspections.
Conclusion
ISO 9626 is crucial in ensuring that stainless steel tubing used in medical applications meets stringent safety and performance standards. Compliance requires a deep understanding of material properties, precision manufacturing, and rigorous quality control.
By implementing the best practices outlined in this guide, manufacturers can meet regulatory expectations, enhance product durability, and ensure patient safety.
For companies involved in medical device production, adhering to ISO 9626 is not just about meeting compliance—it’s about maintaining high-quality standards, ensuring product reliability, and staying competitive in the medical industry.
If you are in the medical device manufacturing sector and need guidance on ISO 9626 compliance, consulting with industry experts or utilizing specialized testing laboratories can help validate your stainless steel tubing against the standard’s requirements.
-
Risk Management Package€149,00
Subscribe to 4EasyReg Newsletter
4EasyReg is an online platform dedicated to Regulatory matters within the medical device, information security and AI-Based business.
We offer a wide range of documentation kits to support your compliance efforts towards a wide range of standards and regulations, such as ISO 13485, EU MDR, ISO 27001, ISO 42001 and much more. . Specifically, in our webshop you will find:
- ISO 13485 Documentation / Compliance Kit
- ISO 27001 Documentation / Compliance Kit
- ISO 42001 Documentation / Compliance Kit
- FDA Cybersecurity Documentation
Within our sister platform QualityMedDev Academy, a wide range of online & self-paced training courses is available, such as for example:
- Complaint Handling and Vigilance Reporting
- Artificial Intelligence in Medical Device. Regulatory Requirements
- Unique Device Identification (UDI) Requirements according to EU MDR
- Clinical Evaluation Process According to EU MDR
- Medical Device SW Verification & Validation
- Risk Management for Medical Devices
- Usability Evaluation for Medical Devices
As one of the leading online platforms in the medical device sector, 4EasyReg offers extensive support for regulatory compliance. Our services cover a wide range of topics, from EU MDR & IVDR to ISO 13485, encompassing risk management, biocompatibility, usability, software verification and validation, and assistance in preparing technical documentation for MDR compliance.
Do not hesitate to subscribe to our Newsletter!